
Yellow Jacket 42036 Series 41 manifold
Series 41 manifold with 3-1/8 inch gauges and a 60-inch PLUS II hose set, scaled for R-32, R-454B, and R-410A. The brass bar that should already be on the truck, with a spare in the cage.
As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure
Loading the stock list…
One Stop Shop Stock
Gauges, scales, vacuum pumps, recovery machines, flares, cutters, and leak detectors.
Category filters
26 parts in Tools

Series 41 manifold with 3-1/8 inch gauges and a 60-inch PLUS II hose set, scaled for R-32, R-454B, and R-410A. The brass bar that should already be on the truck, with a spare in the cage.

Four-valve TITAN manifold with gauges, a color hose set, and a 3/8 inch vacuum hose. Use it when you want a dedicated vacuum port instead of borrowing the center hose.

Four-port SMAN with a large display, micron readings, and pipe clamps in the case. The digital manifold for techs who are done squinting at fluttering needles.

Job Link pressure probes for charging without hanging a manifold on every mini-split. Pair them with a phone when the condenser is on a roof and the gauges are not.

Wireless vacuum gauge that shows the decay, not just a number that looks good while the pump is running. Hang it at the system, not at the pump blank-off.

A straightforward digital micron gauge for the second truck. It does one job: tell you whether the system is actually dry.

Flow meter so the purge is a measured trickle, not a blast that blows the alloy out of the joint. About 2 to 5 SCFH while brazing is the habit to build.

Heated-diode leak detector for the small leaks soap never shows. Change the filter and the sensor on a schedule, not after a week of ghost alarms.

Infrared detector that is less fussy about sensor life than a heated diode. A good second opinion when the DR58 and the soap disagree.

Cloud-connected or not, it is still a heated-diode detector shops trust on small leaks. Keep it in the case. Truck floors kill sensors.

Digital manometer for gas pressure and static pressure. A water column manometer in a drawer does not help the tech on a rooftop.

Job Link probe for return and supply wet-bulb and dry-bulb. Temperature split without humidity is only half the diagnosis.

Wireless charging scale with a platform big enough for a recovery cylinder. Charge and recover by weight instead of by hope.

Twin-cylinder recovery machine for the residential refrigerants still on most calls. Fast enough that it earns a permanent spot next to the charging scale.

Compact recovery machine with a self-purge and selectable auto-stop. A second machine so a truck is not down when the primary one is in the shop.

Two-stage 5 CFM pump with 1/4 inch, 3/8 inch, and 1/2 inch ACME intakes. The everyday evacuation pump for split systems and changeouts.

Two-stage 6 CFM Eliminator pump for techs who want a little more displacement than a 5 CFM on long line sets and multi-zone systems.

8 CFM Fieldpiece pump with a large oil sight and multiple flare intakes. Park it in the cage for the days the truck pump is already on a job.

1/4 inch core remover so vacuum and recovery are not strangled by a Schrader. One lives in every evacuation bag.

Replacement RYB charging hoses, 60 inches, with 1/4 inch flare ends. Retire a hose the day the barrier starts checking bad instead of taping it.

Eccentric flaring tool for 3/16 through 3/4 inch tube, with a clutch that tells you the flare is done. Mini-split work depends on this more than on arm strength.

Small cutter for the copper you cannot swing a full-size tool around. The wheel is a consumable. Replace it when it starts to crush the tube.

Full-size cutter for line sets and the larger soft copper. A clean cut is the start of a flare that does not leak.

CGA-580 nitrogen regulator for purge and pressure testing. A refrigerant gauge set is not a nitrogen regulator.

Fin straightener for the condenser that lost a fight with a weed trimmer or a hail storm. Straight fins move air. Crushed fins do not.

Deburr both the inside and the outside of every cut before you flare or braze. The curl inside the tube becomes a restriction.