Skip to content
One Stop Shop Stock

As an Amazon Associate I earn from qualifying purchases. Affiliate disclosure

One Stop Shop Stock

Stock room starter checklist

124 parts to put on the shelf before the season hits. Par is a starting count for a residential shop, not an order. Walk the cage and check what is actually there.

01 Electrical

17

  • Packard Titan Pro TRCFD455 dual capacitor

    45/5 MFD, 440/370 volt round dual run capacitor. The value that disappears first in July. Keep a stack, not a single spare.

    Par 6Notes

  • Packard Titan Pro 40/5 dual run capacitor

    40/5 MFD round dual run capacitor for the condensers that are not quite a 45/5. Label the bin so nobody grabs the wrong can.

    Par 4Notes

  • Packard Titan Pro 35/5 dual run capacitor

    35/5 MFD round dual run capacitor. Smaller tonnage condensers and a lot of package units still ask for this exact value.

    Par 4Notes

  • Packard Titan Pro 5 MFD run capacitor

    5 MFD oval or round fan-motor run capacitor at 440 volts. Condenser fan motors eat these, and the symptoms look like a bad motor until you test it.

    Par 6Notes

  • Packard 2-pole 30 amp contactor

    Two-pole definite purpose contactor, 30 amp, 24 volt coil. Pitted points on a July afternoon should be a bin pull, not a supply-house run.

    Par 4Notes

  • Packard 1-pole 40 amp contactor

    Single-pole 40 amp contactor with a 24 volt coil for the furnaces and air handlers that switch only one leg.

    Par 3Notes

  • Supco SPP6 hard start kit

    Two-wire hard start kit for single-phase compressors that groan and trip on a hot start. Stock it before a customer asks you to keep resetting the breaker.

    Par 4Notes

  • White-Rodgers 24V fan relay

    24 volt switching relay for blower and fan circuits. A seized relay is a no-cool call that is fixed from the electrical bin.

    Par 3Notes

  • Packard 40VA 24V transformer

    40 VA multi-mount transformer, primary 120/208/240 to a 24 volt secondary. Undersized transformers cook themselves the week a new thermostat goes in.

    Par 3Notes

  • Southwire 12 AWG THHN, black, 500 ft

    Stranded 12 gauge THHN for whip repairs, disconnects, and the condenser circuit you should not be splicing with whatever is on the truck.

    Par 1Notes

  • Southwire 18/8 thermostat wire, 250 ft

    Eighteen-gauge, eight-conductor thermostat cable. Pull eight even when the stat only needs five, so the next add-on is not another fishing job.

    Par 1Notes

  • Wago 221 lever-nut assortment

    Lever connectors for control wiring and the occasional whip splice you can actually reopen. Faster than wire nuts when the panel is full.

    Par 2Notes

  • Ideal Wing-Nut wire connector kit

    A jar of winged wire connectors in the sizes control cabinets actually use. Replace the melted orange one instead of reusing it.

    Par 2Notes

  • Klein CL390 HVAC clamp meter

    Clamp meter that reads the capacitor value in circuit and the amp draw on a compressor common. This is the meter that lives in the truck, not the drawer.

    Par 2Notes

  • Klein NCVT-6 non-contact voltage tester

    Non-contact tester for a quick check before you pull a disconnect or open a cabinet. It is not a meter, and every helper should still have one.

    Par 3Notes

  • Insulated crimp terminal assortment

    Insulated female spades, rings, and butts from 22 to 10 AWG. Contactor coils and capacitor leads fail at the terminal more often than in the wire.

    Par 2Notes

  • 60 amp non-fusible AC disconnect

    NEMA 3R pull-out disconnect, 60 amp, non-fusible. The rusted disconnect at the condenser is a stock part, not a special order.

    Par 2Notes

02 Motors & Fans

7

  • 1/4 HP 1075 RPM condenser fan motor

    208-230 volt, 1/4 horsepower, 1075 RPM condenser fan motor with a reversible rotation plug. The motor you change when the blade spins free and the compressor is fine.

    Par 2Notes

  • 1/6 HP 1075 RPM condenser fan motor

    208-230 volt, 1/6 horsepower condenser fan motor for the smaller residential condensers. Do not substitute a 1/4 and hope the mount lines up.

    Par 2Notes

  • US Motors Rescue multi-HP condenser motor

    Rescue motor that covers a band of horsepower and rotation so one box can finish the call. Read the wiring chart on the carton before it goes on the truck.

    Par 1Notes

  • Genteq Evergreen EM ECM blower motor

    Evergreen replacement ECM for constant-torque blowers. Match the horsepower and the programming, then keep the old module until the new one actually runs.

    Par 1Notes

  • 18 inch condenser fan blade

    Eighteen-inch condenser fan blade, 1/2 inch bore, pitched for the usual residential top-discharge unit. A cracked blade will shake a new motor to death.

    Par 2Notes

  • 10 x 8 double-inlet blower wheel

    Ten by eight inch double-inlet blower wheel. Replace it when the fins are packed or the hub is wallowed out, not just the motor.

    Par 1Notes

  • Condenser fan motor mount kit

    Belly-band and bracket hardware for motors whose OEM mount is cracked or the wrong diameter. A motor without a solid mount is a return call.

    Par 2Notes

03 Controls

8

  • Honeywell Home T6 Pro thermostat

    T6 Pro programmable thermostat, model TH6320U2008, for conventional and heat pump systems. The stat most homeowners can actually operate.

    Par 2Notes

  • White-Rodgers silicon nitride hot surface igniter

    Silicon nitride igniter in the 767A family. Carry more than one. They crack in the truck if you treat the carton like a fitting.

    Par 4Notes

  • Furnace flame sensor rod

    A straight flame-sensor rod for the furnaces that drop out after the igniter glows. Clean one once. Replace it the second time.

    Par 4Notes

  • White-Rodgers universal furnace control

    Universal hot-surface ignition control in the 50M56 family. Match the blower timings to the old board before you call the job done.

    Par 1Notes

  • Honeywell L4064 fan and limit control

    Combination fan and limit for older furnaces that still use a helical element instead of a board. Do not jumper a limit and leave.

    Par 1Notes

  • Strap-on freeze protection thermostat

    Opens the control circuit if the suction line or coil ices up. The cheap part that saves an evaporator and a ceiling.

    Par 2Notes

  • Universal furnace pressure switch

    A multi-range replacement pressure switch for inducer proving. Measure the actual pressure before you condemn the switch you just installed.

    Par 2Notes

  • 10k outdoor temperature sensor

    Outdoor sensor for heat pump balance points and thermostats that lock out auxiliary heat. Mount it out of the sun and off the refrigerant lines.

    Par 2Notes

04 Copper & Fittings

11

  • 1/4 x 3/8 mini-split line set, 25 ft

    Insulated mini-split line set, 1/4 inch liquid and 3/8 inch suction, 25 feet. The length that finishes a single-zone without a coil of leftover copper in the truck.

    Par 4Notes

  • 3/8 x 3/4 line set, 25 ft

    Insulated conventional line set for a typical residential split. Check the suction size on the existing unit before you unroll it.

    Par 2Notes

  • 3/8 inch soft ACR copper, 50 ft

    Fifty feet of 3/8 inch refrigeration-grade soft copper for repairs that should not be made from a cut-up line set.

    Par 1Notes

  • Brass flare nut and union assortment

    Flare nuts and unions from 1/4 through 5/8 inch. Mini-splits leak at tired flares, and the fix is a new nut and a proper flare, not more torque.

    Par 2Notes

  • 1/4 inch access tee with valve core

    Brass access tee for a service port where the factory did not leave you one. Depress the core, braze or flare it in, and replace the core when you are done.

    Par 6Notes

  • 1/4 inch valve cores, 10 pack

    Replacement Schrader cores for access ports. A leaking core is not a low charge. Change the core before you add refrigerant.

    Par 3Notes

  • Harris Stay-Brite 8 solder

    Silver-bearing solder for the joints where brazing heat is a bad idea, including a lot of mini-split and repair work. It is solder, not a substitute for a nitrogen purge.

    Par 2Notes

  • Harris Stay-Silv 15 brazing rods

    15 percent silver brazing alloy for copper-to-copper refrigerant joints. Flow it with nitrogen moving through the line.

    Par 2Notes

  • Harris brazing flux

    Flux for the joints that need it, especially copper to brass. Do not use it as a bandage for a dirty tube.

    Par 2Notes

  • TurboTorch air-acetylene torch kit

    Self-lighting air-acetylene torch for brazing line sets and repair couplings. Keep a full MC tank in the cage so the truck tank is not the only one.

    Par 1Notes

  • 3/8 inch copper coupling assortment

    Wrot copper couplings for 3/8 inch liquid-line repairs. Ream the tube. A ridge inside a coupling is how you restrict a system you just fixed.

    Par 1Notes

05 Filters & IAQ

6

  • Filtrete 16x25x1 MERV 11, 4 pack

    The one-inch size that fits a huge share of returns. MERV 11 is a reasonable stock filter. MERV 13 in a one-inch slot is how you freeze a coil.

    Par 2Notes

  • Filtrete 20x25x1 MERV 11, 4 pack

    Twenty by twenty-five by one inch, four to a pack. The other size that should never be at zero in the cage.

    Par 2Notes

  • Filtrete 16x20x1 MERV 11, 4 pack

    Sixteen by twenty, the size that hides in apartment air handlers. Easy to forget until you are standing in a closet without one.

    Par 2Notes

  • Honeywell 20x25x4 MERV 11 media filter

    Four-inch media for the cabinets that were built for it. Do not slide a one-inch filter into a four-inch rack and call it close enough.

    Par 2Notes

  • Aprilaire 35 humidifier water panel

    Water panel for the common Aprilaire 600 and 700 series. A humidifier with a fossilized pad is just a restriction.

    Par 4Notes

  • 20x20x1 MERV 11 filter, 4 pack

    Square one-inch filters for the returns that are neither 16x25 nor 20x25. A small stack prevents a second trip for a ten-dollar part.

    Par 1Notes

06 Drain & Condensate

10

  • Little Giant VCMA-20ULS condensate pump

    Condensate pump with about 20 feet of lift for air handlers and furnaces that cannot drain by gravity. Check the safety switch wiring before you leave.

    Par 2Notes

  • DiversiTech CP-22 condensate pump

    A 22-foot-lift condensate pump to keep next to the Little Giants. Same job, different mounting feet, so the cage should hold both.

    Par 2Notes

  • RectorSeal Safe-T-Switch SS610E

    Electronic condensate overflow switch sized for mini-splits and primary pans. It shuts the system down before the drywall does the detecting.

    Par 3Notes

  • RectorSeal Safe-T-Switch SS2

    Secondary-pan float switch. Code and common sense both want one anywhere a secondary pan exists. Clip it so it actually floats.

    Par 3Notes

  • Nu-Calgon Pan Treat tablets

    Condensate pan tablets that slow the slime that plugs a trap in August. They are not a substitute for cleaning the pan.

    Par 4Notes

  • DiversiTech 30x36 secondary drain pan

    Metal secondary pan for an air handler in a closet or attic. Pitch it, trap it, and put a float switch in it.

    Par 1Notes

  • EZ Trap clear condensate trap

    Clear inline trap so you can see the slime instead of guessing. A stock item for every air handler that uses vinyl or PVC.

    Par 4Notes

  • 3/8 inch clear vinyl tubing, 100 ft

    Clear vinyl for condensate drains and trap repairs. Do not use it on refrigerant, and do not leave a low spot that becomes a second trap.

    Par 1Notes

  • 3/4 inch PVC fitting assortment

    Tees, elbows, couplings, and adapters in 3/4 inch schedule 40. Condensate repairs should not wait on a hardware-store run.

    Par 1Notes

  • Condensate drain brush

    Flexible brush for the slime you can reach before you cut the line apart. Use it, then tablet the pan.

    Par 2Notes

07 Refrigeration Parts

8

  • Sporlan 3-ton R-410A TXV

    Externally equalized 3-ton thermostatic expansion valve for R-410A coils. Confirm the tonnage and the connection style before it gets brazed in.

    Par 2Notes

  • Sporlan 2-ton R-410A TXV

    Externally equalized 2-ton R-410A TXV for the smaller coils. A 3-ton valve on a 2-ton coil is not a close match.

    Par 1Notes

  • Sporlan Catch-All C-083-S filter drier

    Liquid-line Catch-All for a typical residential split. Replace the drier every time the system is open. That is the whole point of stocking them.

    Par 6Notes

  • Sporlan Catch-All C-163-S filter drier

    Higher-capacity Catch-All for longer line sets and light commercial liquid lines. Keep a few beside the C-083 bin.

    Par 3Notes

  • Sporlan See-All sight glass

    Liquid-line sight glass with a moisture indicator. Bubbles are not automatically low charge, but a yellow indicator is moisture. Know which one you are looking at.

    Par 3Notes

  • Sporlan bi-flow filter drier

    Bi-flow drier for heat pumps, where flow reverses. A standard liquid-line drier on a heat pump is the wrong part.

    Par 2Notes

  • 1/4 inch refrigerant ball valve

    Flare ball valve for isolating a gauge set or a recovery setup without dumping the hoses. One per truck, extras in the cage.

    Par 4Notes

  • R-410A Chatleff TXV power head

    Bolt-on power element for Chatleff-style R-410A valves. Sometimes the power head is the failure, and the valve body can stay.

    Par 1Notes

08 Tools

18

Gauges & Meters

  • Yellow Jacket 42036 Series 41 manifold

    Series 41 manifold with 3-1/8 inch gauges and a 60-inch PLUS II hose set, scaled for R-32, R-454B, and R-410A. The brass bar that should already be on the truck, with a spare in the cage.

    Par 2Notes

  • Fieldpiece MG44 wireless micron gauge

    Wireless vacuum gauge that shows the decay, not just a number that looks good while the pump is running. Hang it at the system, not at the pump blank-off.

    Par 2Notes

  • Supco VG64 digital vacuum gauge

    A straightforward digital micron gauge for the second truck. It does one job: tell you whether the system is actually dry.

    Par 1Notes

  • Nitrogen purge flow meter

    Flow meter so the purge is a measured trickle, not a blast that blows the alloy out of the joint. About 2 to 5 SCFH while brazing is the habit to build.

    Par 1Notes

  • Fieldpiece DR58 leak detector

    Heated-diode leak detector for the small leaks soap never shows. Change the filter and the sensor on a schedule, not after a week of ghost alarms.

    Par 1Notes

  • Fieldpiece SDMN6 dual-port manometer

    Digital manometer for gas pressure and static pressure. A water column manometer in a drawer does not help the tech on a rooftop.

    Par 1Notes

  • Fieldpiece JL3RH psychrometer probe

    Job Link probe for return and supply wet-bulb and dry-bulb. Temperature split without humidity is only half the diagnosis.

    Par 2Notes

Scales

  • Fieldpiece SR47 wireless refrigerant scale

    Wireless charging scale with a platform big enough for a recovery cylinder. Charge and recover by weight instead of by hope.

    Par 1Notes

Vacuum & Recovery

  • Appion G5Twin recovery machine

    Twin-cylinder recovery machine for the residential refrigerants still on most calls. Fast enough that it earns a permanent spot next to the charging scale.

    Par 1Notes

  • Robinair 15500 VacuMaster vacuum pump

    Two-stage 5 CFM pump with 1/4 inch, 3/8 inch, and 1/2 inch ACME intakes. The everyday evacuation pump for split systems and changeouts.

    Par 1Notes

  • Appion valve core removal tool

    1/4 inch core remover so vacuum and recovery are not strangled by a Schrader. One lives in every evacuation bag.

    Par 2Notes

  • Yellow Jacket PLUS II 60-inch hose set

    Replacement RYB charging hoses, 60 inches, with 1/4 inch flare ends. Retire a hose the day the barrier starts checking bad instead of taping it.

    Par 2Notes

Shop tools

  • CPS BlackMax BFT850 flaring tool

    Eccentric flaring tool for 3/16 through 3/4 inch tube, with a clutch that tells you the flare is done. Mini-split work depends on this more than on arm strength.

    Par 2Notes

  • RIDGID 151 close-quarters tube cutter

    Small cutter for the copper you cannot swing a full-size tool around. The wheel is a consumable. Replace it when it starts to crush the tube.

    Par 2Notes

  • Imperial large tube cutter

    Full-size cutter for line sets and the larger soft copper. A clean cut is the start of a flare that does not leak.

    Par 1Notes

  • Western Enterprises nitrogen regulator

    CGA-580 nitrogen regulator for purge and pressure testing. A refrigerant gauge set is not a nitrogen regulator.

    Par 1Notes

  • Supco fin comb

    Fin straightener for the condenser that lost a fight with a weed trimmer or a hail storm. Straight fins move air. Crushed fins do not.

    Par 2Notes

  • Inner-outer copper deburring tool

    Deburr both the inside and the outside of every cut before you flare or braze. The curl inside the tube becomes a restriction.

    Par 2Notes

09 Safety & PPE

7

  • 3M SecureFit safety glasses

    Clear safety glasses that stay on a sweaty face. Coil cleaner and a slipping wrench both end up at eye level.

    Par 6Notes

  • ANSI A4 cut-resistant gloves

    Cut-resistant gloves for sheet metal, fins, and the furnace cabinet edge that always finds a knuckle. They are not chemical gloves.

    Par 4Notes

  • Nitrile gloves, box of 100

    Chemical-resistant disposables for coil cleaner, pan treatments, and whatever grew in the drain. Stock a size that actually fits the crew.

    Par 2Notes

  • 3M 8511 N95 respirator, 10 pack

    Valved N95 for attic insulation, old filters, and dusty returns. They are not a refrigerant respirator. They are still worth having on the truck.

    Par 2Notes

  • Lockout/tagout kit

    Breaker lock, hasp, and tags. The disconnect you pulled is not locked until it is locked. Tags without a lock are a suggestion.

    Par 1Notes

  • 50-person jobsite first aid kit

    A real kit for cuts from fins and burns from a torch, not a tin of three bandages. Check it twice a year and replace what got used.

    Par 1Notes

  • 3M Peltor X4A earmuffs

    Earmuffs for generators, vacuum pumps in a mechanical room, and the condenser that sits next to your head on a ladder.

    Par 2Notes

10 Consumables

13

  • Nashua 322 foil tape

    HVAC foil tape for duct board, start collars, and the occasional emergency on a return. It is not a substitute for mastic on a joint that has to last.

    Par 6Notes

  • Foil mastic tape

    Butyl mastic tape for ducts and boots where foil tape peels in a season. Press it. It does not stick to dust.

    Par 4Notes

  • Hardcast duct mastic, 1 gallon

    Water-based duct mastic for sealing trunks, boots, and the plenum joint that tape will not hold. Brush it on metal that is actually clean.

    Par 1Notes

  • K-Flex cork insulation tape

    Cork tape for sweating suction lines, bulb wells, and the odd noise. It is not line-set insulation, and it is not a leak fix.

    Par 4Notes

  • ArmaFlex 3/8 inch ID tube insulation

    Closed-cell insulation, 1/2 inch wall, for 3/8 inch liquid and small suction lines. Glue the seams. A split seam sweats on the ceiling.

    Par 8Notes

  • ArmaFlex 7/8 inch ID tube insulation

    Closed-cell insulation for 7/8 inch suction lines. The size people forget until the line set is already in the wall.

    Par 4Notes

  • UV-black 8 inch cable ties, 100

    Ultraviolet-resistant black ties for line sets, whips, and low voltage. White household ties turn to dust on a condenser.

    Par 4Notes

  • Nu-Calgon Evap Foam no-rinse

    No-rinse evaporator foam for coils you cannot wash into a drain you trust. Read the label. It is not a condenser cleaner.

    Par 4Notes

  • Nu-Calgon Nu-Brite coil cleaner

    Alkaline condenser cleaner for outdoor coils. It needs a rinse and it needs eye protection. Do not spray it on an evaporator.

    Par 2Notes

  • Nu-Calgon Cal-Blue Plus

    Bubble leak detector that stays where you put it and does not disappear in a breeze. Use it after the electronic detector finds the neighborhood.

    Par 4Notes

  • RectorSeal No. 5 pipe thread sealant

    Soft-set thread sealant for pipe threads. It is not a flare-nut compound and it does not belong inside a refrigerant system.

    Par 2Notes

  • Blue Monster PTFE thread tape

    Thick PTFE tape for water and condensate threads. Wrap it on male threads, in the direction you tighten.

    Par 6Notes

  • Oatey yellow gas-line PTFE tape

    Yellow PTFE tape rated for gas piping. Do not use the white water tape on a gas valve and do not use this on refrigerant flares.

    Par 2Notes

11 Fasteners & Hangers

8

  • 3/8-16 zinc all-thread, 6 ft

    Six-foot lengths of 3/8-16 rod for hanging air handlers, unit heaters, and strut. Cut it square. A crooked end eats the nut.

    Par 10Notes

  • Unistrut P1000, 10 ft

    1-5/8 inch slotted strut, ten feet, for hanging equipment and building a rack that is not made of scrap wood.

    Par 4Notes

  • 3/8 inch beam clamps

    Beam clamps that take 3/8 inch rod without drilling a bar joist you do not own. Torque them. A spun clamp drops an air handler.

    Par 10Notes

  • Copper tube cushion clamps

    Cushioned clamps for 3/8 and 3/4 inch tube so line sets do not telegraph into the structure. Metal straps on bare suction lines sweat and rot.

    Par 2Notes

  • Hex-head self-drilling screws

    Sheet-metal screws in the lengths that hold duct, boxes, and condenser tops. A mixed bin beats a coffee can of mystery screws.

    Par 2Notes

  • 1/4 x 1-3/4 inch concrete screws

    Concrete screws for pads, brackets, and disconnects on block. Use the right bit. A dull bit makes a hole that will not hold.

    Par 2Notes

  • Mini-split wall bracket

    Powder-coated wall bracket rated for a residential mini-split condenser. Level it, and do not hang the unit on drywall anchors.

    Par 2Notes

  • Insulated line-set J-hooks

    J-hooks that carry an insulated line set without crushing the armaflex. Space them so the line does not sag into a trap.

    Par 10Notes

12 Storage & Organization

7

  • Akro-Mils 44-drawer parts cabinet

    Small-parts cabinet for cores, wire nuts, terminals, and the screws that otherwise live in open cups. Label the drawers the day you fill them.

    Par 2Notes

  • Hanging storage bins, large, 6 pack

    Open hanging bins for capacitors, contactors, and motors you need to see from the aisle. Clear fronts beat a closed box you never open.

    Par 4Notes

  • 72 inch steel shelving, 5 shelf

    Industrial shelving tall enough for line-set cartons and pumps without stacking them on the floor. Bolt it to the wall.

    Par 2Notes

  • Brother P-touch PT-D210

    Laminated-label printer for bins, shelves, and the disconnect you just replaced. Handwritten tape lasts until the first humid week.

    Par 1Notes

  • Brother TZe 1/2 inch label tape

    Black-on-white laminated tape for the PT-D210. Buy it in multiples. The maker is useless the day the cassette runs out.

    Par 4Notes

  • Write-on bin labels, 2 x 3, 100

    A pad of bin labels for the week the label maker is in someone's truck. Use the part name and the size, not 'misc'.

    Par 2Notes

  • Stackable capacitor and contactor bin

    A shallow bin dedicated to dual-run capacitors and contactors so the values stay separated. Mixing 35/5 and 45/5 in one tub is how the wrong can gets installed.

    Par 4Notes

13 Office Supplies

4

  • Hammermill letter copy paper, case

    A case of 8.5 by 11 inch, 20 lb copy paper for work orders, invoices, and the printer at the dispatch desk. Keep one case unopened so a Monday morning does not start with a hardware-store run.

    Par 1Notes

  • Adams 2-part carbonless work order book

    Two-part carbonless work orders for the calls that still get written by hand. One copy stays in the book, one goes with the tech or the customer.

    Par 2Notes

  • Letter-size storage clipboard

    A clipboard with a storage compartment for the work order, the permit, and a pen. One belongs in each truck and two more at the dispatch counter.

    Par 3Notes

  • Sharpie fine point, black, 12 pack

    Black fine-point Sharpies for labeling boxes, writing on tape, and marking a filter size. They disappear from the desk, so buy them by the box.

    Par 2Notes

The rest of the variants live in the One Stop Shop Stock catalog. This page is the first fill, not the whole cage.